EXPERIMENTAL PROCEDURE


 

  1. The experiment is started at a condenser saturation temperature of 20oC.
  2. Program 1 is entered and the evaporator load is increased approximately 10%.
  3. Return to the main menu and Program 2 is entered. “no print out” is selected and    the three parameters; 5. Condensing Temperature; 2. Refrigerant Flow Rate; and 14. Cooling Water Flow Rate is displayed.
  4. The condensing temperature of 20oC may be maintained by small adjustments of the cooling water flow rate. The system is stable when all three parameters show generally horizontal lines (approximately 1 minute).
  5. Return to the main menu and Program 1 is selected with print-out option (raw and calculated data) when the system is stabilized.
  6. Evaporator load is increased (by 10%) and the results are printed out. Repeat until evaporator load is 60%.

 